KNX Sensor


The knx sensor platform allows you to monitor KNX sensors.

The knx component must be configured correctly, see KNX Component.

There is currently support for the following KNX data point types:

Condition KNX Datapoint Type Unit of measurement Data type
Temperature 9.001 °C 2 Byte Float
Speed (Wind speed) 9.005 m/s 2 Byte Float
Illuminance (Lux) 9.004 Lux 2 Byte Float

To use your KNX sensor in your installation, add the following to your configuration.yaml file:

# Example configuration.yaml entry
sensor:
  - platform: knx
    type: temperature
    address: 1/0/3

  - platform: knx
    name: Wind speed
    type: speed_ms
    address: 1/0/0

  - platform: knx
    name: Lux
    type: illuminance
    address: 1/0/1

Configuration variables:

  • type (Required): The type of the sensor. See table above for available options.
  • address (Required): The address of the sensor on the bus.
  • name (Optional): The name to use in the frontend.
  • minimum (Optional): Minimum sensor value who gets processed. Defaults to a hardcoded default values.
  • maximum (Optional): Maximum sensor value who gets processed. Defaults to a hardcoded default.